Flash Timer
What’s this?
Flash is used extensively as one of the digits for accessing various features. Flash is actually momentarily
breaking of the station current loop. If this break time is of optimum level, the Vision senses it rightly as a flash.
But, if the time is more, it can be wrongly taken as disconnection. On the other hand, if the flash timer is set to
a higher value, a genuine disconnection will take longer time. Some are known to use longer flash time. You
have to program the station flash timer with little higher value than the flash timer used by the telephone
connected to it.
How to program?
Use following command to program flash timer:
4102-1-Station-Flash Timer
Where,
Station is from 00 to 08.
Flash Timer is from 300 to 900.
Use following command to program same flash timer for all the stations:
4102-*-Flash Timer
By default, Flash timer is 600 msec.