130 Matrix SETU ATA211 System Manual
Configuring Multi-Stage Dialing
For this feature to work, at each site where the SETU ATA211 is installed, do the following:
Make sure that Auto Attendant or Direct Inward Dialing is enabled on the FXO port of the PBX on which
SETU ATA211 is interfaced.
Enable Automatic Number Translation on the desired SIP Trunk of SETU ATA211.
Configure the Automatic Number Translation Table.
Set the DTMF ON Time, DTMF OFF Time.
Enable ‘Play Routing Tone’ in the System Parameters, if required.
Set the Pause Timer to the desired value.
To configure Multistage Dialing at each site where the SETU ATA211 is connected,
Open Jeeves.
Log in as Admin with your password.
Click the Basic Settings link.
Under Basic Settings, click SIP.
Now, click the SIP Trunk number tab (SIP Trunk 1, 2, or 3) on which you want to apply Multi-stage Dialing.
Click the More button to view all parameters on this page.
Scroll to Advanced.
Enable Automatic Number Translation on this SIP Trunk.
To configure the Automatic Number Translation Table, click the arrow icon.